Leave Your Message

Low Temp Air Cooled Chiller from China Suppliers - High Efficiency, Energy Saving Factory Equipment

Introducing our high-performance cooling solutions featuring renowned European and American compressors, known for their exceptional cooling efficiency and low noise levels. Our products are designed with energy-saving technology, ensuring safe, stable, and environmentally friendly operation for long-lasting durability, We prioritize the use of international brand electrical components to guarantee machine stability and longevity, providing you with a reliable solution for your cooling needs. Our cryogenic pumps are sourced from well-known brands, offering large displacement with low power consumption, making them both energy-efficient and durable. Customizable pump materials are available upon request to meet your specific requirements, As a leading manufacturer based in China, we take pride in being one of the top suppliers in the industry, committed to delivering high-quality factory products that meet international standards. Discover the difference our reliable and efficient cooling systems can make for your business today!

    Design Advantages

    Host selection of European, American new world famous brand compressor, high cooling efficiency, low-low noise, energy saving, safe and stable, environmentally friendly and durable.

    Control of electrical appliances to control the use of international brands, to ensure the machine is stable, long life, safe and reliable.

    Well-known brand cryogenic pumps, large displacement, low power consumption, energy saving, durable, life and pump material can be optional. (Optional on request)

    Well-known brands of low noise external rotor fan or axial fan, low noise, large air volume, energy saving environmentally friendly and durable.

    Number of precision temperature controller with display, easy to operate, simple and intuitive. Can precisely control the temperature 1℃, the set temperature range 5℃-40℃, can be directly analyzed the health unit. (Can be configured according to user requirements control systems.)

    Standard tank evaporator coil (optional stainless steel plate evaporator or dry shell and tube evaporator), quick and easy cleaning and maintenance.

    Using high-performance condenser shell and tube heat exchanger (optional stainless steel plate heat exchanger), built-in high efficiency heat exchanger tube teeth, reasonable design, heat transfer effect is good;

    Efficient corrosion radiator, coupled with efficient heat dissipation from the corrosion of aluminum foil and efficient heat transfer screw threaded brass components, the use of secondary fins flanging machinery rose tube heat exchanger technology and advanced production line manufacturing to ensure quality and efficient energy-saving.

    Electrostatic spray enclosure, Europeanization design, elegant appearance plate with quick disassembly, easy to use and maintain. Unit can be tailored according to customer requirements.

    PC-ACL Low Temp Air Cooled Chiller Parameter Table

    Type Temperature PC-3ACL PC-5ACL PC-6ACL PC-8ACL PC-10ACL PC-12ACL PC-15ACL PC-20ACL PC-25ACL PC-30ACL PC-40ACL
    Refrigerating capacity KW
    50HZ/60HZ
    -10℃ 3.8/4.6 6.3/7.6 7.5/9 9.1/10.9 13.2/15.8 16.1/19.3 19.5/23.4 26.4/31.7 32.2/38.6 39/46.8 52/62.4
    -20℃ 1.9/2.3 3.0/3.6 4/4.8 6/7.2 7.1/8.5 8/9.6 13.9/16.7 16.9/20.3 20.8/25 24.4/29.3 30.8/37
    -30℃ 1.0/1.2 1.6/1.9 1.9/2.3 2.7/3.2 3.2/3.8 3.8/4.6 6.1/7.3 9.4/11.4 12.1/14.5 14.3/17.1 19/22.8
    -35℃ 0.67/0.8 1.04/1.25 1.5/1.8 2.3/2.8 2.8/3.4 3/3.6 4.3/5.2 6.35/7.62 8.3/10 10.1/12.1 13.3/16
    Evaporator Frozen water(m³/h) -10℃ 0.65/0.79 1.1/1.3 1.3/1.5 1.6/1.9 2.3/2.7 2.8/3.3 3.4/4.1 4.5/5.4 5.6/6.7 6.7/8.1 9/10.8
    -20℃ 0.33/0.4 0.52/0.62 0.69/0.83 1.1/1.3 1.23/1.47 1.38/1.65 2.39/2.87 2.85/3.45 3.57/4.3 4.2/5.04 5.3/6.36
    -30℃ 0.17/0.21 0.28/0.33 0.33/0.4 0.47/0.55 0.55/0.65 0.65/0.8 1.1/1.3 1.6/2 2.1/2.5 2.46/2.9 3.3/3.9
    -35℃ 0.12/0.14 0.18/0.22 0.26/0.31 0.4/0.48 0.48/0.58 0.52/0.62 0.72/0.89 1.1/1.31 1.43/1.72 1.74/2.09 2.3/2.76
    Type Dry shell and tube / Stainless steel plate heat exchanger
    Diameter inch 1” 1” 1” 1” 1-1/2” 1-1/2” 2” 2” 2” 2-1/2” 2-1/2”
    Input power KW 3.18 4.86 5.61 7.25 9.4 10.9 13.5 18.8 22.55 28.5 37.5
    Maximum current A 7.8 12 13.7 18 23 26.5 33 46 55 69 91
    Power 3PH~380V/415V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ)
    Refrigerant Name R22(R404A/R507)
    Control Outside the balanced thermal expansion valve
    Compressor Type Hermetic scroll(piston)
    Power KW 2.25 3.75 4.5 6 7.5 9 11.3 7.5×2 9.37×2 11.3×2 30
    Condenser Type Efficient aluminum finned copper sleeve+Stainless steel plate evaporator
    Pump Power kw 0.75 0.75 0.75 0.75 1.1 1.1 1.5 2.2 2.2 4 5.5
    Maximum lift m 20 20 20 20 20 20 20 20 20 25 20
    Security Compressor motor overheating protection, overload protection device unit, high and low pressure protection device, frost protection devices, power reverse phase/phase protection, exhaust temperature, over-temperature protection, flow switches

    Notes:

    1. Cooling capacity is based on: the cooling air inlet temperature of 30℃ to 38℃. chilled water out of the water out of the water temperature 3℃ to 8℃; cooling temperature at 50℃.

    2. The cooling temperature is not higher than 35℃ environment. Specification Dimensions above are subject to change without notice.

    PC-WCL Low Temp Water Cooled Chiller Parameter Table

    Type Temperature PC-3WCL PC-5WCL PC-6WCL PC-8WCL PC-10WCL PC-12WCL PC-15WCL PC-20WCL PC-25WCL PC-30WCL PC-40WCL
    Refrigerating capacity KW
    50HZ/60HZ
    -10℃ 4.5/5.4 7.7/9.3 9.1/11 11.7/14.1 16.1/19.3 19.1/22.9 23.3/28 32.2/38.6 38.2/45.8 46.6/56 62.5/75
    -20℃ 2.7/3.24 4.1/4.92 5.3/6.24 8.1/9.72 9.8/11.76 10.6/12.72 13.6/16.32 20.4/24.48 25.00/28.80 29.4/35.28 38.5/46.2
    -30℃ 1.31/1.57 2.1/2.52 2.8/3.36 4.3/5.36 4.9/5.88 5.6/6.72 7.9/9.48 11.2/13.44 13.7/16.44 16.1/19.32 21.2/25.44
    -35℃ 0.85/1.02 1.3/1.56 1.9/2.28 2.8/3.36 3.3/3.96 3.8/3.96 5.3/6.36 7.8/9.36 9.4/11.28 13.8/16.56 17.8/21.36
    Condenser Type shell and tube exchanger
    (m³/h)Frozen water -10℃ 1/2.1 1.7/2.06 2.03/2.44 2.62/3.14 3.6/4.32 4.27/5.12 5.2/6.24 7.23/8.67 8.54/10.25 10.4/12.5 14/16.8
    -20℃ 0.61/0.74 0.92/1.11 1.09/1.31 1.82/2.18 2.03/2.43 2.37/2.84 3.04/3.65 4.56/5.48 5.6/6.71 6.58/7.9 8.61/10.33
    -30℃ 0.31/0.37 0.49/0.58 0.65/0.78 1/1.2 1.14/1.36 1.3/1.56 1.84/2.2 2.61/3.13 3.19/3.82 3.74/4.49 4.93/6
    -35℃ 0.2/0.24 0.31/0.36 0.44/0.52 0.65/0.78 0.77/0.92 0.89/1.06 1.23/1.48 1.81/2.17 2.18/2.62 3.2/3.84 4.13/4.96
    Diameter inch 1-1/2” 1-1/2” 1-1/2” 1-1/2” 1-1/2” 1-1/2” 2” 2” 2-1/2” 3” 3”
    Evaporator Type Dry shell and tube/ Stainless steel plate heat exchanger
    Frozen water(m³/h) -10℃ 0.77/0.93 1.33/1.59 1.56/1.88 2.01/1.73 2.77/3.32 3.28/3.94 4/4.8 5.56/6.65 6.57/7.89 8.01/9.62 10.75/12.3
    -20℃ 0.47/0.56 0.71/0.85 0.91/1.1 1.4/1.67 1.69/2.02 1.82/2.19 2.34/2.81 3.51/4.21 4.3/5.16 5.06/6.07 6.62/7.94
    -30℃ 0.23/0.27 0.36/0.44 0.48/0.58 0.74/0.89 0.84/1.01 0.96/1.16 1.36/1.63 1.93/2.31 2.36/2.83 2.77/3.32 3.65/4.48
    -35℃ 0.15/0.18 0.22/0.27 0.33/0.39 0.48/0.58 0.57/0.68 0.65/0.78 0.92/1.1 1.34/1.61 1.62/1.94 2.37/2.85 3.06/3.67
    Diameter inch 1” 1” 1” 1” 1-1/2” 1-1/2” 2” 2” 2-1/2” 2-1/2” 3”
    Input power KW 3 4.5 5.25 6.75 8.6 10.1 12.8 4.56 21 26.5 34
    Maximum current A 7.5 11 13 16.5 21 25 31 42 51 64 83
    Power 3PH~380V/415V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ)
    Refrigerant Name R22(R404A/R507)
    Control Outside the balanced thermal expansion valve
    Compressor Type Hermetic scroll(piston)
    Power KW 2.25 3.75 4.5 6 7.5 9 11.3 7.5×2 9.4×2 11.3×2 30
    Pump Power kw 0.75 0.75 0.75 0.75 1.1 1.1 1.5 2.2 2.2 4 4
    Maximum lift m 18 18 18 18 20 20 20 20 20 25 20
    Security Compressor motor overheating protection, overload protection device unit, high and low pressure protection device, frost protection devices, power reverse phase/phase protection, exhaust temperature, over-temperature protection, flow switches

    Notes:

    1. Cooling capacity is based on: chilled water out of the water temperature 3℃ to 8℃, condensing temperature at 40℃; cooling water inlet and outlet water temperature of 25℃/30℃.

    Cooling water temperature range: 18℃ to 35℃; cooling water out of the water temperature 3.5℃ to 10℃. Specification Dimensions above are subject to change without notice.

    Frequently Asked Questions (FAQ)

    What are the primary design advantages of these low-temperature chillers?

    These chillers feature compressors from world-famous European and American brands, ensuring high cooling efficiency, low noise, and stable operation. They also utilize international brand electrical controls, cryogenic pumps, low-noise external rotor or axial fans, and electrostatic spray enclosures for easy disassembly and maintenance.

    What is the temperature control range and precision of these units?

    The units are equipped with a precision temperature controller with a clear display, allowing for easy operation. It can precisely control the temperature down to 1℃, with a set temperature range of 5℃ to 40℃.

    What types of evaporators are standard or optional for these chillers?

    The standard configuration features a tank evaporator coil. Depending on user requirements, a stainless steel plate evaporator or a dry shell and tube evaporator can be selected for quick and easy cleaning and maintenance.

    On what conditions is the cooling capacity of the PC-ACL Air Cooled Chiller based?

    The cooling capacity is calculated based on a cooling air inlet temperature of 30℃ to 38℃, chilled water outlet temperature of 3℃ to 8℃, and a condensing temperature of 50℃. The cooling environment temperature should not exceed 35℃.

    What safety protection devices are built into these chiller systems?

    To ensure safe and reliable operation, the units include compressor motor overheating protection, overload protection, high and low pressure protection, frost protection, power reverse phase/phase protection, exhaust temperature protection, over-temperature protection, and flow switches.

    Can these low-temperature chillers be customized?

    Yes, the chiller units can be tailored and configured according to specific customer requirements, including customizable control systems and cryogenic pump materials.

    Leave Your Message