Leave Your Message

Industrial Cold Water Machine - -30°C to +5°C - China Manufacturers & Suppliers | High-Performance Freezer Factory

,

Scope of Application

,

The low temperature freezer, designed and developed by Manster Company, is a state-of-the-art refrigeration solution ideal for various industries, including pharmaceuticals, chemicals, and biotechnology. This China-manufactured equipment features a versatile temperature range adjustable from -30 degrees to +5 degrees, accommodating diverse storage requirements. Our low temperature freezers are equipped with high-performance imported compressors, ensuring exceptional cooling capacity and reliability. As a leading supplier in the industry, our factory is committed to delivering top-quality refrigeration equipment that sets the standard for the new generation of low-temperature freezers.

,

    Design Advantages

    Compact Structure & Smooth Operation

    Condenser and evaporator units utilize efficient heat transfer tubes. The host selection features imported, high-efficiency hermetic scroll compressors, offering a compact, lightweight design with flexible installation. With fewer moving parts, it delivers high energy efficiency, low noise, low vibration, and stable performance, operating 20%-30% more efficiently than reciprocating compressors.

    Improved Energy Control System

    The conditioning units start and stop according to load changes to maximize energy efficiency. The computer control system adjusts the unit's energy output based on thermal load changes. By monitoring the difference between actual load and user settings, the microcomputer quickly determines the required energy, optimizing multi-system operations to minimize consumption even at partial loads.

    Simple & Intuitive Interface

    Equipped with a microcomputer program controller (Chinese/digital display), allowing users to start the unit with a simple touch. The panel displays operating status and text parameters at a glance. No professional operator is required. It precisely controls temperature within 1℃ (special accuracy up to 0.1℃) with a setting range of 5℃-50℃.

    Microcomputer Protection

    Features comprehensive safety functions, including compressor coil overcurrent protection, pump overcurrent protection, cold water flow switch, low cooling protection, high water temperature protection, compressor overload protection, frequent start/stop prevention, abnormal voltage protection, and high/low pressure protection.

    Multiple Protection, Safe & Reliable

    Beyond the internal compressor protection module providing under/over voltage, phase failure, and overload protection, the refrigeration system is equipped with advanced pressure control units and other safety devices to make operation completely foolproof.

    Optimized Mobility & Efficiency

    Engineered for maximum refrigeration efficiency while keeping noise to a minimum to meet environmental standards. Air-cooled chiller pumps are highly mobile and easy to relocate without assembling cooling towers.

    Easy Installation & Setup

    All components are fully installed and run-tested at the factory. Refrigerants and refrigeration oils are pre-filled, so users simply need to connect the waterway and electrical circuit to put the unit into use, saving time and setup costs.

    Parameter Table (1)

    Type

    PC-3WC

    PC-4WC

    PC-5WC

    PC-6WC

    PC-8WC

    PC-10WC

    PC-12WC

    PC-15WC

    PC-15WC(D)

    PC-20WC(D)

    Refrigerating capacity

    Kcal/h 50HZ/60HZ

    8170

    11266

    14018

    16340

    22532

    28036

    32680

    43172

    42140

    56760

    Kcal/h 50HZ/60HZ

    9804

    13519

    16822

    19608

    27038

    33643

    39216

    51806

    50568

    68112

    KW 50HZ/60HZ

    9.5

    13.1

    16.3

    19

    26.2

    32.6

    38

    50.2

    49

    66

    KW 50HZ/60HZ

    11.4

    15.72

    19.56

    22.8

    31.44

    39.12

    45.6

    60.24

    58.8

    79.2

    Input power (KW)

    3.07

    3.87

    5.3

    5.95

    7.75

    10.6

    11.9

    16.25

    15.85

    19.71

    Maximum current (A)

    7.5

    9.4

    12.9

    14.4

    18.8

    25.7

    28.9

    39.4

    38.2

    47.8

    Power

    3PH~380V/415V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ)

    Refrigerant

    Name

    R22/R407C/134a/404A/410A

    Control

    Capillary/external balance of thermal expansion valve

    Compressor

    Type

    Hermetic scroll(piston)

    Power(KW)

    2.7

    3.5

    4.55

    5.2

    7

    4.55×2

    5.2×2

    11.25

    5.55×2

    8.96×2

    Condenser

    Type

    Efficient aluminum finned copper sleeve+Stainless steel plate evaporator

    cooling air flow(m³/h)

    2.1

    2.9

    3.6

    4.2

    5.7

    7.1

    8.3

    11

    10.8

    14.4

    2.4

    3.3

    4.1

    4.8

    6.6

    8.3

    9.6

    12.8

    12.5

    16.7

    Diameter(inch)

    1-1/2”

    1-1/2”

    1-1/2”

    1-1/2”

    1-1/2”

    1-1/2”

    1-1/2”

    2”

    2”

    2”

    Evaporator

    Type

    Tank coil/Dry shell and tube / Stainless steel plate evaporator

    Frozen water(m³/h)

    1.63

    2.25

    2.8

    3.27

    4.5

    5.6

    6.53

    8.63

    8.43

    11.35

    1.96

    2.7

    3.36

    3.92

    5.4

    6.73

    7.84

    10.36

    10.1

    13.62

    Capacity(L)

    60

    60

    60

    90

    150

    200

    200

    330

    330

    330

    Diameter(inch)

    1”

    1”

    1”

    1”

    1-1/2”

    2”

    2”

    2”

    2”

    2”

    Pump

    Power(kw)

    0.37

    0.37

    0.75

    0.75

    0.75

    0.75

    0.75

    1.5

    1.5

    1.5

    Maximun lift(m)

    22

    22

    30

    30

    25

    25

    25

    28

    28

    28

    Maximum flow(m³/h)

    5.4

    5.4

    8.1

    8.1

    8.1

    13.5

    13.5

    25.2

    25.2

    25.2

    Security

    Compressor motor overheating protection, overload protection device unit, high and low pressure protection device, frost protection devices, power reverse phase/phase protection, exhaust temperature protection, over-temperature protection, flow switches

    Parameter Table (2)

    Type

    PC-25WC(D)

    PC-30WC(D)

    PC-30WC(T)

    PC-40WC(D)

    PC-40WC(F)

    PC-50WC(D)

    PC-50WC(F)

    Refrigerating capacity

    Kcal/h 50HZ/60HZ

    66048

    83420

    85140

    114036

    113520

    134504

    132096

    Kcal/h 50HZ/60HZ

    79258

    100104

    102168

    136843

    136224

    161405

    158515

    KW 50HZ/60HZ

    76.8

    98

    99

    132.6

    132

    156.4

    153.6

    KW 50HZ/60HZ

    92.16

    116.4

    118.8

    159.12

    158.4

    187.68

    184.32

    Input power (KW)

    23.8

    30.99

    30.63

    41.31

    39.59

    52.7

    48.7

    Maximum current (A)

    61.7

    75.2

    74.8

    100.3

    96.6

    127.9

    119.7

    Power

    3PH~380V/415V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ)

    Refrigerant

    Name

    R22/R407C/134a/404A/410A

    Control

    Capillary/external balance of thermal expansion valve

    Compressor

    Type

    Hermetic scroll(piston)

    Power(KW)

    10.8×2

    13.62×2

    8.96×3

    13.62×2

    18.78×4

    23.6×2

    10.8×4

    Condenser

    Type

    Efficient aluminum finned copper sleeve+Stainless steel plate evaporator

    (m³/h)cooling air flow

    17

    21.4

    21.7

    29.3

    28.9

    35

    33.9

    19.6

    24.7

    25.1

    33.8

    34.4

    40.4

    39.1

    (inch)Diameter

    2”

    2-1/2”

    2-1/2”

    3”

    3”

    3”

    3”

    Evaporator

    Type

    Tank coil/Dry shell and tube / Stainless steel plate evaporator

    (m³/h)Frozen water

    13.21

    16.68

    17.02

    22.8

    22.7

    26.9

    26.41

    15.85

    20.02

    20.43

    27.36

    27.24

    32.27

    31.7

    Capacity(L)

    350

    450

    450

    580

    580

    620

    620

    (inch)Diameter

    2”

    2-1/2”

    2-1/2”

    3”

    3”

    3”

    3”

    Pump

    Power(kw)

    2.2

    2.2

    2.2

    3.7

    3.7

    5.5

    5.5

    (m) Maximun lift

    28

    30

    30

    30

    30

    32

    32

    (m³/h)(Maximum flow

    25.2

    36

    36

    36

    36

    40

    40

    Security

    Compressor motor overheating protection, overload protection device unit, high and low pressure protection device, frost protection devices, power reverse phase/phase protection, exhaust temperature protection, over-temperature protection, flow switches

    Notes
    • Cooling capacity is based on: chilled water inlet and outlet water temperature 12℃/7℃, the cooling air inlet temperature of 30℃/35℃.
    • Scope of work: chilled water temperature range: 5℃ to 35℃; chilled water out of the water temperature: 3℃ to 18℃.
    • In condensing, the ambient temperature is not higher than 35℃ using (non-standard chilled ambient temperature maximum temperature of 5℃ requires custom ordering).
    • These models can be customized according to customer requests.
    • Specification Dimensions above are subject to change without notice.

    Frequently Asked Questions (FAQ)

    What are the core design advantages of the hermetic scroll compressor?

    The hermetic scroll compressor has fewer moving parts, utilizes flexible compression, and offers high energy efficiency with low noise and operating costs. Because the compression process is continuous without pulses, the unit provides stable performance, minimal vibration, and smooth running characteristics, achieving 20%-30% higher efficiency than reciprocating compressors.

    How does the energy control system optimize power consumption?

    The unit starts and stops automatically based on load changes. The integrated microcomputer monitors the difference between the actual thermal load and the user settings to quickly adjust the energy output. In multi-system configurations, it optimizes output to ensure the lowest energy consumption even under partial load.

    What safety protections are integrated into the microcomputer controller?

    The controller provides multiple built-in protections, including compressor coil overcurrent protection, pump overcurrent protection, cold water flow switch, low cooling protection, high water temperature protection, compressor overload protection, frequent start/stop prevention, abnormal voltage protection, and high/low pressure protection.

    Is the chiller unit easy to install?

    Yes. All components are pre-assembled and run-tested at the factory, and the systems are pre-charged with refrigerants and refrigeration oils. Users only need to connect the external waterway and electrical circuit to put the unit into operation, reducing installation and commissioning time.

    What is the standard operating temperature range?

    The standard chilled water temperature range is 5℃ to 35℃, and the outlet water temperature range is 3℃ to 18℃. The ambient temperature for the condenser should not exceed 35℃ under standard operating conditions.

    Can these chiller units be customized?

    Yes. These models can be customized according to specific customer requirements, including configurations for non-standard ambient temperatures (such as a maximum ambient temperature of 5℃).

    Leave Your Message