High-Quality PCB Chiller from China Suppliers and Factory with Precision Temperature Control ±1℃

Introducing our premium temperature control unit, powered by a renowned international compressor brand. This unit is designed with built-in security protection to ensure low noise operation and stable performance, making it an energy-efficient and durable choice for any setting. As a trusted supplier from China, we prioritize safety and environmental protection in our manufacturing processes, Our temperature controller features a precise display for easy operation. Its intuitive design allows anyone to use it without the need for professional training. This unit can accurately control temperatures within a range of ±1℃, with settings from 5℃ to 50℃, allowing for direct health unit analysis. Tailored configurations are available to meet specific user requirements, reinforcing our commitment as a leading factory in the industry

    Design Advantages

    A host adopt international famous brand compressor, built-in security protection, low noise, stable performance, energy saving, safety and environmental protection durable.

    Number of precision temperature controller with display, easy to operate, simple and intuitive, no professional can be used normally. Can precisely control the temperature±1℃, the set temperature range 5℃-50℃, can be directly analyzed the health unit. (According to user requirements configuration control system)

    Electrical parts are the international well-known brand products, ensure the machine work stability, long service life, safe and reliable.

    All stainless steel tube or stainless steel tank evaporator plate evaporator to prevent the generation of solid water and other metal impurities in the transportation process.

    Well-know brand of low noise external rotor fan or axialfan, low noise,large air volume, environmentally friendly power and durable.

    Rump using stainless steel high-lift pump of pfants, starting torque, stable performance,clean water.(the pump head can be optional according to customer requirements). Pump Set DC drive circuit, le in CNC machine fool spInde inoperative pumps stopped running, ensure that the spindle is at a standstill there will be to condensation occurs.

    Air-cooled high-efficiency radiator corrosion,coupled with efficient heat dissipation from the corrosion of aluminum foll and efficient heat trans ferscrew threaded brass components the use of secondary fins flanging machinery rose tube heat exchanger technology and advanced production line manufacturing, quality assurance energy-efficient and environmentally friendly.

    Unit is equipped with multiple protection devices, more safe and reliable operation of the unit.

    Product specifications and diverse, range, supporting the use of the laser power for different machines.

    Installation is simple, no matter the height of the chiller and the host matches, can boot normally use.

    Electrostatic spray enclosure, Europeanization design, elegant appearance plate with quick disassembly, easy to use and maintain.

    PCB Chiller Parameter Table

    Type PC-1.5AC PC-2AC PC-3AC PC-4AC PC-5AC PC-6AC
    Refrigerating capacity Kcal/h 3182 4833 7181 9288 11988 14534
    50HZ/60HZ 3874 5800 8617 11146 14386 17441
    KW 3.7 5.62 8.35 10.8 13.94 16.9
    50HZ/60HZ 4.4 6.74 10.02 12.96 16.73 20.28
    Input power KW 2 2.25 3.27 4.07 5.75 6.45
    Maximum current A 12 13.6 8.2 10.1 13.8 15.5
    Power 1PH-220V/3PH-200V/380V 50HZ/60HZ 3PH~380V/415V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ)
    Refrigerant Name R22/R407C/R34a/404A/410A
    Control Capillary/external balance of thermal expansion valve
    Compressor Type Hermetic rotary/ piston Hermetic scroll(piston)
    (KW)Power 1.3 1.73 2.7 3.5 4.55 5.25
    Condenser Type Efficient aluminum finned copper sleeve+Stainless steel plate evaporator
    (m³/h)cooling air flow 1500 2000 3000 4000 5000 6000
    (KW)Fan power 0.15 0.15 0.14×2 0.14×2 0.19×2 0.19×2
    Evaporator Type Stainless steel plate evaporator/stainless steel coil water tank
    (m³/h)Frozen water 0.64 0.97 1.44 1.86 2.4 2.91
    Capacity(L) 0.76 1.16 1.72 2.23 2.88 3.49
    27 27 50 60 60 110
    (inch)Diameter 1/2” 1/2” 1” 1” 1” 1”
    Pump Power(KW) 0.37 0.37 0.37 0.37 0.75 0.75
    Maximum lift(m) 22 22 22 22 30 30
    Maximum flow(m³/h) 5.4 5.4 5.4 5.4 8.1 8.1
    Security Compressor overheating protection, over current protection, high and low pressure protection, over temperature protection, traffic protection, phase sequence/phase loss protection, low level protection, flow switches

    Notes

    1. Cooling capacity is based on: chilled water inlet and outlet water temperature 12℃/7℃, the cooling air inlet temperature of 30℃/35℃.

    2. Scope of work: chilled water temperature range: 5℃ to 85℃; chilled water out of the water temperature difference: 3℃ to 18℃.

    3. In condensing the ambient temperature is not higher than 35℃ using.

    4. These models can be customized according to customer requirements to produce custom-made.

    5. Specification Dimensions above are subject to change without notice.

    Frequently Asked Questions (FAQ)

    Q: What is the temperature control accuracy of the PCB chiller?

    The chiller features a precision temperature controller that can control the temperature within ±1℃, with a set temperature range of 5℃ to 50℃.

    Q: What materials are used in the evaporator construction to prevent impurities?

    The unit utilizes all stainless steel tube or stainless steel tank/plate evaporators to prevent the generation of solid water and other metal impurities during transportation.

    Q: What type of refrigerants can be used with this chiller?

    The compatible refrigerants for these chiller units include R22, R407C, R34a, 404A, and 410A.

    Q: What built-in safety protections does the unit have?

    It is equipped with multiple protection devices, including compressor overheating protection, over current protection, high and low pressure protection, over temperature protection, traffic protection, phase sequence/phase loss protection, low level protection, and flow switches.

    Q: Can these chiller units be customized according to specific requirements?

    Yes, these models can be customized and custom-made according to specific customer requirements.

    Q: What is the standard working scope for the chilled water temperature?

    The chilled water temperature range is 5℃ to 85℃, with a chilled water output temperature difference of 3℃ to 18℃.