Features
-
Efficient semi-hermetic screw compressor, the unit running smoothly, low noise.
-
Suction cooling the motor running low temperature, long motor life.
-
Using high-quality bearings, bearing life of at least 40,000 hours.
-
Built-in oil separator, smaller, better.
-
You can secure the implementation phase or energy stepless adjustable from 0% to 100% range, the maximum saving power resources.
-
Using high-performance condenser shell and tube heat exchanger (optional stainless steel plate heat exchanger), built-in high efficiency heat exchanger tube teeth, reasonable design, heat transfer effect is good;
-
Using high-performance evaporator shell and tube heat exchanger (optional stainless steel plate heat exchanger), built-in high efficiency heat exchanger tube teeth, reasonable design, heat transfer effect is good;
-
Suitable for R22, R134a, R404A refrigerant other.
-
Fewer moving parts. Low failure rate.
-
Can be equipped with devices to further improve the economy compressor cooling capacity and efficiency.
-
Can be equipped with spray cooling means to extend the application range of the compressor.
-
Can be equipped with an oil cooling means to increase the efficiency of the compressor and compressor applications.
Easy to use, control features and more
-
Power control procedures can be achieved, energy regulation program, stop control procedures, downtime, fault diagnosis, operation time statistics, operating status display and reboot recovery procedures;
-
Has full control, protection functions together, simple interface and operation of the whole Chinese characteristics
-
Computer LCD touch screen controller; can reflect the health unit, the operation more convenient
-
Can be connected to the building control system (with optional control module) or remote control
-
With the chilled water pumps, cooling water pumps, cooling towers chain control function
-
Host highly automated, no special setting operation and management personnel.
LS-WSCS Single head Water Cooled Screw Chiller
Type |
LS-30WSCS |
LS-40WSCS |
LS-50WSCS |
LS-60WSCS |
LS-70WSCS |
LS-80WSCS |
LS-90WSCS |
LS-100WSCS |
LS-110WSCS |
LS-120WSCS |
||
Refrigerating capacity |
Kcal/h |
86000 |
116100 |
150500 |
163400 |
197800 |
219300 |
258000 |
301000 |
322500 |
356900 |
|
kw |
100 |
135 |
175 |
190 |
230 |
255 |
300 |
350 |
375 |
415 |
||
Input power |
KW |
22 |
30 |
37 |
42 |
51 |
56 |
65 |
75 |
80 |
90 |
|
Maximum current |
A |
40 |
53 |
67 |
73 |
89 |
97 |
109 |
126 |
137 |
153 |
|
Power |
3PH~380V/415V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ) |
|||||||||||
Refrigerant |
Name |
R22(R134a/R407C/R404A) |
||||||||||
(kg)charge Amount |
17 |
22 |
27 |
33 |
38 |
43 |
50 |
55 |
60 |
66 |
||
Control |
External balanced temperature thermal expansion valve |
|||||||||||
Compressor |
Type |
Semi-hermetic screw |
||||||||||
(KW)Power |
22 |
30 |
37 |
42 |
51 |
56 |
65 |
75 |
80 |
90 |
||
Start |
Y-△ |
|||||||||||
Energy regulation range(%) |
0-33-66-100 |
0-25-50-75-100 |
||||||||||
Evaporator |
Type |
Dry shell and tube (Stainless steel plate evaporator) |
||||||||||
(m³/h)Frozen water |
17.2 |
23.2 |
30 |
32.7 |
40 |
43.9 |
51.6 |
60.2 |
64.5 |
71.4 |
||
(Kpa) Water resistance |
35 |
35 |
35 |
38 |
40 |
42 |
42 |
45 |
45 |
43 |
||
(inch)Diameter |
3” |
3” |
3” |
3” |
4” |
4” |
4” |
4” |
4” |
5” |
||
Condenser |
Type |
Low wind noise external rotor fan or aluminum axial fan |
||||||||||
Fans |
Type |
21 |
28.4 |
36.6 |
40 |
48.3 |
53.5 |
62.8 |
73 |
78.2 |
86.8 |
|
Power |
kw |
42 |
42 |
42 |
43 |
42 |
43 |
43 |
45 |
45 |
45 |
|
Airflow |
m³/h |
3” |
3” |
3” |
4” |
4” |
4” |
4” |
4” |
5” |
5” |
|
Security |
Compressor motor overheating protection, overload protection device unit, high and low pressure protection device, frost protection devices, power reverse phase/phase protection, exhaust temperature, over-temperature protection, flow switches |
|||||||||||
LS-WSCS Double headed Water Cooled Screw Chiller
Type |
LS-60WSCD |
LS-80WSCD |
LS-100WSCD |
LS-120WSCD |
LS-140WSCD |
LS-160WSCD |
LS-180WSCD |
LS-200WSCD |
LS-220WSCD |
LS-240WSCD |
||
Refrigerating capacity |
Kcal/h |
86000 |
116100 |
150500 |
163400 |
197800 |
219300 |
258000 |
301000 |
322500 |
356900 |
|
kw |
200 |
270 |
350 |
380 |
460 |
510 |
600 |
700 |
750 |
830 |
||
Input power |
KW |
44 |
60 |
74 |
84 |
102 |
112 |
130 |
150 |
160 |
180 |
|
Maximum current |
A |
40 |
53 |
67 |
73 |
89 |
97 |
109 |
126 |
137 |
153 |
|
Power |
3PH~380V/415V~50HZ/60HZ(3PH~200V/220V 50HZ/60HZ) |
|||||||||||
Refrigerant |
Name |
R22(R134a/R407C/R404A) |
||||||||||
(kg)charge Amount |
17×2 |
22×2 |
27×2 |
33×2 |
38×2 |
43×2 |
50×2 |
55×2 |
60×2 |
66×2 |
||
Control |
External balanced temperature thermal expansion valve |
|||||||||||
Compressor |
Type |
Semi-hermetic screw |
||||||||||
(KW)Power |
22×2 |
30×2 |
37×2 |
42×2 |
51×2 |
56×2 |
65×2 |
75×2 |
80×2 |
90×2 |
||
Start |
Y-△ |
|||||||||||
Energy regulation range(%) |
0-33-66-100 |
0-25-50-75-100 |
||||||||||
Evaporator |
Type |
Dry shell and tube (Stainless steel plate evaporator) |
||||||||||
(m³/h)Frozen water |
34 |
46 |
60 |
65 |
79 |
88 |
103 |
120 |
120 |
143 |
||
(Kpa) Water resistance |
35 |
35 |
35 |
38 |
40 |
42 |
42 |
45 |
45 |
43 |
||
(inch)Diameter |
4” |
4” |
4” |
5” |
5” |
6” |
6” |
6” |
8” |
8” |
||
Condenser |
Type |
Low wind noise external rotor fan or aluminum axial fan |
||||||||||
Fans |
Type |
42 |
57 |
73 |
80 |
97 |
107 |
126 |
146 |
156 |
174 |
|
Power |
kw |
42 |
42 |
42 |
43 |
42 |
43 |
43 |
45 |
45 |
45 |
|
Airflow |
m³/h |
4” |
4” |
4” |
5” |
6” |
4”×2 |
4”×2 |
4”×2 |
5”×2 |
5”×2 |
|
Security |
Compressor motor overheating protection, overload protection device unit, high and low pressure protection device, frost protection devices, power reverse phase/phase protection, exhaust temperature, over-temperature protection, flow switches |
|||||||||||
Frequently Asked Questions
What are the advantages of the semi-hermetic screw compressor?
The semi-hermetic screw compressor offers highly efficient operation, smooth running with low noise levels, suction motor cooling to maintain low temperatures, and a long service life with premium bearings designed to last at least 40,000 hours.
Which refrigerants are compatible with the LS-WSCS screw chiller?
These chillers are designed to be highly adaptable and are suitable for R22, R134a, R404A, and other common refrigerants depending on your specific cooling requirements.
How does the energy regulation program save power?
The chiller features an adjustable energy regulation range (either 0-33-66-100% or 0-25-50-75-100% depending on the model), allowing the system to match the actual load demand precisely and maximize power resource savings.
Can the chiller be integrated into a building control system?
Yes, the system can be connected to building control systems or remote controls using an optional control module, and it supports chain control for chilled water pumps, cooling water pumps, and cooling towers.
What safety protection devices are built into this screw chiller?
The unit is equipped with comprehensive security features including compressor motor overheating protection, overload protection, high/low pressure protection, frost protection, power reverse phase/phase protection, exhaust over-temperature protection, and flow switches.
What is the main difference between the Single head and Double headed models?
The Single head models (WSCS) utilize a single compressor configuration for standard load requirements, while the Double headed models (WSCD) feature dual compressors for larger refrigeration capacities, higher airflow, and enhanced redundancy.