Our low temperature freezer is a cutting-edge refrigeration solution designed by Manster Company, a leading China manufacturer and supplier known for delivering high-quality equipment for industries such as pharmaceuticals, chemicals, and biotechnology. This state-of-the-art freezer boasts an adjustable temperature range from -30 degrees to +5 degrees, ensuring optimal storage conditions for sensitive materials. Equipped with a powerful imported compressor, it guarantees exceptional cooling capacity and reliability. As a premier factory in the refrigeration sector, we are committed to providing innovative solutions that meet the rigorous demands of our clients.

,

    Design Advantages

    1

    Compact & Smooth Operation

    Condenser and evaporator units use efficient heat transfer tubes. The host features imported, highly efficient hermetic scroll compressors, offering compact structure, small size, and lightweight installation. With fewer moving parts and flexible compression technology, it delivers high energy efficiency, low operating costs, low noise, and minimal vibration.

    2

    Energy Control System

    Conditioning units automatically start and stop based on load changes to maximize energy savings. The microcomputer control system monitors the difference between actual load and user settings to adjust energy output dynamically. Multi-system setups optimize output to ensure minimal energy consumption at both full and partial loads.

    3

    Simple & Intuitive Interface

    Equipped with a microcomputer program controller (digital display), allowing users to easily start the unit by touching the panel. The screen displays real-time operating status and parameters in text format. Temperature can be precisely controlled to 1℃ (special requests up to 0.1℃) within a range of 5℃-50℃.

    4

    Microcomputer Protection

    Features comprehensive protection functions: compressor coil overcurrent protection, pump overcurrent protection, cold water flow switch, low-temperature protection, high-temperature water protection, compressor overload protection, frequent start/stop protection, abnormal voltage protection, and high/low pressure protection.

    5

    Multiple Safeguards

    In addition to the internal compressor protection module (providing under-voltage, phase failure, and overload protection), the refrigeration system pressure control units and safety devices ensure foolproof and reliable operations under all working conditions.

    6

    Optimized Mobility

    Designed to maximize refrigeration efficiency while reducing noise to meet strict environmental requirements. Air-cooled chiller pumps are highly mobile and easy to move without the need to assemble cooling towers.

    7

    Easy Installation

    All components are fully installed and run-tested at the factory, including the pre-filling of refrigerants and refrigeration oils. Users simply need to connect the waterway and electrical circuit to put the unit into immediate use, reducing setup time.

    Parameter Table (1)

    Type

    PC-3WC

    PC-4WC

    PC-5WC

    PC-6WC

    PC-8WC

    PC-10WC

    PC-12WC

    PC-15WC

    PC-15WC(D)

    PC-20WC(D)

    Refrigerating capacity

    Kcal/h
    50HZ/60HZ

    8170

    11266

    14018

    16340

    22532

    28036

    32680

    43172

    42140

    56760

    9804

    13519

    16822

    19608

    27038

    33643

    39216

    51806

    50568

    68112

    KW
    50HZ/60HZ

    9.5

    13.1

    16.3

    19

    26.2

    32.6

    38

    50.2

    49

    66

    11.4

    15.72

    19.56

    22.8

    31.44

    39.12

    45.6

    60.24

    58.8

    79.2

    Input power

    KW

    3.07

    3.87

    5.3

    5.95

    7.75

    10.6

    11.9

    16.25

    15.85

    19.71

    Maximum current

    A

    7.5

    9.4

    12.9

    14.4

    18.8

    25.7

    28.9

    39.4

    38.2

    47.8

    Power

    3PH~380V/415V~50HZ/60HZ (3PH~200V/220V 50HZ/60HZ)

    Refrigerant

    Name

    R22/R407C/134a/404A/410A

    Control

    Capillary/external balance of thermal expansion valve

    Compressor

    Type

    Hermetic scroll (piston)

    Power (KW)

    2.7

    3.5

    4.55

    5.2

    7

    4.55×2

    5.2×2

    11.25

    5.55×2

    8.96×2

    Condenser

    Type

    Efficient aluminum finned copper sleeve + Stainless steel plate evaporator

    Cooling air flow (m³/h)

    2.1

    2.9

    3.6

    4.2

    5.7

    7.1

    8.3

    11

    10.8

    14.4

    2.4

    3.3

    4.1

    4.8

    6.6

    8.3

    9.6

    12.8

    12.5

    16.7

    Diameter (inch)

    1-1/2”

    1-1/2”

    1-1/2”

    1-1/2”

    1-1/2”

    1-1/2”

    1-1/2”

    2”

    2”

    2”

    Evaporator

    Type

    Tank coil/Dry shell and tube / Stainless steel plate evaporator

    Frozen water (m³/h)

    1.63

    2.25

    2.8

    3.27

    4.5

    5.6

    6.53

    8.63

    8.43

    11.35

    1.96

    2.7

    3.36

    3.92

    5.4

    6.73

    7.84

    10.36

    10.1

    13.62

    Capacity (L)

    60

    60

    60

    90

    150

    200

    200

    330

    330

    330

    Diameter (inch)

    1”

    1”

    1”

    1”

    1-1/2”

    2”

    2”

    2”

    2”

    2”

    Pump

    Power (kw)

    0.37

    0.37

    0.75

    0.75

    0.75

    0.75

    0.75

    1.5

    1.5

    1.5

    Maximum lift (m)

    22

    22

    30

    30

    25

    25

    25

    28

    28

    28

    Maximum flow (m³/h)

    5.4

    5.4

    8.1

    8.1

    8.1

    13.5

    13.5

    25.2

    25.2

    25.2

    Security

    Compressor motor overheating protection, overload protection device unit, high and low pressure protection device, frost protection devices, power reverse phase/phase protection, exhaust temperature protection, over-temperature protection, flow switches

    Parameter Table (2)

    Type

    PC-25WC(D)

    PC-30WC(D)

    PC-30WC(T)

    PC-40WC(D)

    PC-40WC(F)

    PC-50WC(D)

    PC-50WC(F)

    Refrigerating capacity

    Kcal/h
    50HZ/60HZ

    66048

    83420

    85140

    114036

    113520

    134504

    132096

    79258

    100104

    102168

    136843

    136224

    161405

    158515

    KW
    50HZ/60HZ

    76.8

    98

    99

    132.6

    132

    156.4

    153.6

    92.16

    116.4

    118.8

    159.12

    158.4

    187.68

    184.32

    Input power

    KW

    23.8

    30.99

    30.63

    41.31

    39.59

    52.7

    48.7

    Maximum current

    A

    61.7

    75.2

    74.8

    100.3

    96.6

    127.9

    119.7

    Power

    3PH~380V/415V~50HZ/60HZ (3PH~200V/220V 50HZ/60HZ)

    Refrigerant

    Name

    R22/R407C/134a/404A/410A

    Control

    Capillary/external balance of thermal expansion valve

    Compressor

    Type

    Hermetic scroll (piston)

    Power (KW)

    10.8×2

    13.62×2

    8.96×3

    13.62×2

    18.78×4

    23.6×2

    10.8×4

    Condenser

    Type

    Efficient aluminum finned copper sleeve + Stainless steel plate evaporator

    Cooling air flow (m³/h)

    17

    21.4

    21.7

    29.3

    28.9

    35

    33.9

    19.6

    24.7

    25.1

    33.8

    34.4

    40.4

    39.1

    Diameter (inch)

    2”

    2-1/2”

    2-1/2”

    3”

    3”

    3”

    3”

    Evaporator

    Type

    Tank coil/Dry shell and tube / Stainless steel plate evaporator

    Frozen water (m³/h)

    13.21

    16.68

    17.02

    22.8

    22.7

    26.9

    26.41

    15.85

    20.02

    20.43

    27.36

    27.24

    32.27

    31.7

    Capacity (L)

    350

    450

    450

    580

    580

    620

    620

    Diameter (inch)

    2”

    2-1/2”

    2-1/2”

    3”

    3”

    3”

    3”

    Pump

    Power (kw)

    2.2

    2.2

    2.2

    3.7

    3.7

    5.5

    5.5

    Maximum lift (m)

    28

    30

    30

    30

    30

    32

    32

    Maximum flow (m³/h)

    25.2

    36

    36

    36

    36

    40

    40

    Security

    Compressor motor overheating protection, overload protection device unit, high and low pressure protection device, frost protection devices, power reverse phase/phase protection, exhaust temperature protection, over-temperature protection, flow switches

    Notes

    1. Cooling capacity basis: Chilled water inlet and outlet water temperature 12℃/7℃; cooling air inlet temperature of 30℃/35℃.

    2. Scope of work: Chilled water temperature range: 5℃ to 35℃; chilled water out of the water temperature: 3℃ to 18℃.

    3. Ambient temperature limits: In condensing, the ambient temperature should not be higher than 35℃ (non-standard chilled ambient temperature maximum temperature of 5℃ requires custom ordering).

    4. Customization: These models can be customized according to specific customer production requirements.

    5. Specifications changes: Dimensions and specifications listed above are subject to change without prior notice.

    Frequently Asked Questions (FAQ)

    What are the primary design advantages of the scroll compressor used in this unit?
    The unit utilizes an imported, highly efficient hermetic scroll compressor. It features fewer moving parts, which results in low noise, small vibration, high energy efficiency, and low operating costs. Its overall efficiency is 20%-30% higher than traditional reciprocating compressors.
    What kind of protection features does the microcomputer controller provide?
    The microcomputer controller provides multiple safety protections, including compressor coil overcurrent protection, pump overcurrent protection, cold water flow switches, low-temperature protection, high water temperature protection, compressor overload protection, frequent start/stop prevention, abnormal voltage protection, and high/low pressure protection.
    What is the standard operating temperature range for the chilled water?
    The standard chilled water temperature range is from 5℃ to 35℃, and the outlet water temperature range is from 3℃ to 18℃.
    Are these industrial chillers easy to install at the factory site?
    Yes, they are highly convenient to install. All components are pre-installed, run-tested, and pre-filled with refrigerants and refrigeration oils at the factory. Users only need to connect the waterway and the electrical circuits to put the unit into operation.
    Can these chiller units be customized for non-standard ambient temperatures?
    Yes, these units can be customized to meet specific customer requirements. For example, if you require a non-standard chilled ambient maximum temperature of 5℃, it can be ordered and custom-manufactured.

    Leave Your Message