Leave Your Message

China PC-AC Series Air Cooled Industrial Cold Water Machine - Suppliers & Factory for Low Temperature Freezers

Scope of Application

,

The low-temperature freezer, developed by Manster Company, represents the latest generation of refrigeration equipment tailored for various industries, including pharmaceuticals, chemicals, and biotechnology. With an adjustable temperature range from -30 degrees to +5 degrees, this freezer ensures optimal storage conditions for sensitive materials. Featuring a high-capacity imported compressor, it delivers reliable cooling performance, making it an ideal choice among Chinese suppliers and factories seeking advanced low-temperature solutions.

    Design Advantages

    1. High-Efficiency Energy-Saving Design

    Equipped with imported scroll compressors and high-efficiency heat exchange tubes, the unit features a compact structure and a small footprint. The fully enclosed scroll compressor has fewer moving parts and flexible operation, offering 20%-30% higher energy efficiency compared to traditional reciprocating compressors. It operates with low noise, minimal vibration, and excellent stability, enabling pulse-free continuous operation.

    2. Intelligent Load Adjustment

    The adaptive energy control system monitors real-time thermal load changes on the client side and intelligently adjusts output power. Through precise microcomputer calculations of the difference between actual load and set values, it optimizes energy consumption during multi-system collaboration, ensuring high efficiency under both full and partial load conditions.

    3. User-Friendly Interface

    Features a dual-display (Chinese/numeric) microcomputer controller with a touch-operated panel and clear menu guidance. Real-time operation status and parameters are displayed, with temperature control accuracy of ±1°C (optional ±0.1°C) and an adjustable range of 5-50°C. Easy operation for non-professionals, making it ideal for healthcare and other specialized environments.

    4. Comprehensive Safety Protection

    Integrated multi-protection systems include compressor overcurrent protection, pump overload protection, low water flow protection, ultra-high water temperature protection, voltage anomaly protection, high/low pressure protection, and start-stop frequency protection, ensuring safe operation.

    5. Multi-Layered Safety Assurance

    In addition to the compressor’s built-in protection module, the unit is equipped with complete electrical protection and refrigeration system monitoring, providing comprehensive safeguards against phase loss, over/under voltage, overload, and more.

    6. Eco-Friendly and Quiet Operation

    System-optimized design significantly reduces operational noise. Air-cooled models can be used directly without cooling towers or pumps, meeting environmental standards and enabling flexible installation.

    7. Plug-and-Play

    Pre-assembled, performance-tested, and pre-charged with refrigerant before leaving the factory. Users only need to connect water and electrical pipelines for quick deployment, greatly reducing installation and commissioning time.

    Parameter Table 1

    Type PC-3AC PC-4AC PC-5AC PC-6AC PC-8AC PC-10AC PC-12AC PC-15AC
    Project Specifications
    Refrigerating capacity kcal/h 7181 9288 11988 14534 18576 23994 29068 38270
    50HZ/60HZ 8617 11146 14386 17441 22291 28793 34882 45924
    KW 8.35 10.8 13.94 16.9 21.6 27.9 33.8 44.5
    50HZ/60HZ 10.02 12.96 16.73 20.28 25.92 33.48 40.56 53.4
    Input power KW 3.27 4.07 5.75 6.45 8.25 11.5 12.9 17.45
    Maximum current A 8.2 10.1 13.8 15.5 20 27.9 31.3 42.4
    Power 3PH~380V 1415V-50HZ 160HZ(3PH~200V 1220V 50HZ 160HZ)
    Refrigerant Name R22 / R407CM34a /404A / 410A
    Control Capillary / external balance of thermal expansion valve
    Compressor Type Hermetic scroll(piston)
    Power(KW) 2.7 3.5 4.55 5.25 7 7.5 9 11.25
    Condenser Type Efficient aluminum finned copper sleeve+Stainless steel plate evaporator
    (m³/h) Cooling air flow 3000 4000 5000 6000 8000 10000 12000 15000
    (KW) Fan power 0.19x1 0.19x1 0.19x2 0.19x2 0.42x2 0.42x2 0.42x2 0.42x3
    Evaporator Type Tank coil / Dry shell and tube / Stainless steel plate evaporator
    (m³/h) Frozen water 1.44 1.86 2.4 2.91 3.71 4.8 5.81 7.65
    1.72 2.23 2.88 3.49 4.46 5.76 7 9.18
    Capacity(L) 50 60 60 110 120 200 200 270
    (inch) Diameter 1” 1” 1” 1” 1-1/2” 2” 2” 2”
    Pump (kw) Power 0.37 0.37 0.75 0.75 0.75 0.75 0.75 1.5
    (m) Maximum lift 22 22 30 30 25 25 25 28
    (m³/h) Maximum flow 5.4 5.4 8.1 8.1 8.1 13.5 13.5 35.2
    Security Compressor motor overheating protection, overload protection device unit high and low pressure protection device, frost protection devices, power reverse phase/phase protection, exhaust protection, over-temperature protection, low switches

    Parameter Table 2

    Type PC-15AC (D) PC-20AC (D) PC-25AC PC-30AC (D) PC-30AC (T) PC-40AC (D) PC-40AC (F) PC-50AC (D) PC-50AC (F)
    Project Specifications
    Refrigerating capacity Kcal/h 36120 49966 58480 74734 74922 98040 99760 119024 116960
    50HZ/60HZ 43344 59959 70176 89681 89990 117648 119712 142829 140352
    KW 42 58.1 68 86.9 87.2 114 116 138.4 136
    50HZ/60HZ 50.4 69.72 81.6 104.28 104.64 136.8 139.2 166.08 163.2
    Input power KW 17.1 21.73 25.4 33.39 33.1 44.91 43.3 57.3 54
    Maximum current A 43.5 52.7 63.7 81 80.2 109 106 135.5 128.5
    Power 3PH~380V / 415V~50HZ / 60HZ(3PH~200V 1220V 50HZ 160HZ)
    Refrigerant Name R22/R407C1134a/404A/410A
    Control Capillary / external balance of thermal expansion valve
    Compressor Type Hermetic scroll(piston)
    Power(KW) 0.55x2 8.96x2 10.8x2 13.62x2 8.96x3 18.78x2 8.96x4 23.6x2 10.8x4
    Condenser Type Efficient aluminum finned copper sleeve+Stainless steel plate evaporator
    (m³/h) Cooling air flow 15000 20000 25000 30000 30000 40000 40000 50000 50000
    (KW) Fan power 0.42x3 0.19x6 0.42x6 0.42x6 0.42x6 0.6x6 0.6x6 0.78x6 0.78x6
    Evaporator Type Tank coil / Dry shell and tube / Stainless steel plate evaporator
    (m³/h) Frozen water 7.22 10 11.69 14.94 15 19.6 19.95 23.8 23.4
    8.67 11.99 14.03 17.93 18 23.52 23.96 28.6 28.1
    Capacity(L) 270 350 350 420 420 580 580 580 580
    Diameter(inch) 2” 2” 2-1/2” 2-1/2” 2-1/2” 3” 3” 3” 3”
    Pump (kw) Power 2.2 1.5 1.5 2.2 2.2 3.7 3.7 5.5 5.5
    (m) Maximum lift 28 28 28 30 30 30 30 32 32
    (m³/h) Maximum flow 25.2 25.2 25.2 36 36 36 36 40 40
    Security Compressor motor overheating protection, overload protection device unit high and low pressure protection device, frost protection devices, power reverse phase/phase protection, exhaust protection, over-temperature protection, flow switches

    Notes

    1. Cooling capacity is based on: chilled water inlet and outlet water temperature 12℃/7℃, the cooling air inlet temperature of 30℃/35℃.

    2. Scope of work: chilled water temperature range: 5℃ to 35℃; chilled water out of the water temperature: 3℃ to 18℃.

    3. In condensing the ambient temperature is not higher than 35℃ using (non standard chilled ambient temperature maximum temperature of 5℃, need to order production).

    4. These models can be customized according to customer to produce custom-made.

    5. Specification Dimensions above are subject to change without notice.

    Frequently Asked Questions

    What is the temperature control accuracy of this chiller series?
    The unit is equipped with a microcomputer controller that offers a standard temperature control accuracy of ±1°C, with an option to upgrade to ±0.1°C. The temperature adjustment range is between 5°C and 50°C.
    Does this cooling system require a cooling tower or pump installation?
    No. The air-cooled models feature a system-optimized design that does not require external cooling towers or cooling pumps, making them ideal for flexible installations and reducing space requirements.
    What refrigerants are compatible with these units?
    These chillers are compatible with a wide range of refrigerants, including R22, R407C, R134a, R404A, and R410A, depending on your specific environmental and application requirements.
    Is the system plug-and-play upon delivery?
    Yes, the unit is pre-assembled, performance-tested, and pre-charged with refrigerant at the factory. Users only need to connect the water and electrical pipelines to begin operation immediately.
    What safety protections are integrated into the chiller?
    The system features a multi-protection setup, including compressor overcurrent, pump overload, low water flow, ultra-high water temperature, voltage anomalies, high/low pressure, and start-stop frequency protection.
    Can these cooling units be customized?
    Yes, all models in this series can be customized according to specific customer requirements to produce custom-made configurations tailored to your industrial or healthcare environment.

    Leave Your Message